Should you need bast furnace/cupolda furnace for lead acid battery recycling,please contact us now.
Contact information:
curbing888@hotmail.com; wechat: curbing1970; Whatsapp:https://wa.me/8613923774083.
Video of cupola furnace for lead acid battery recycling. This cupola furnace can smelt paste, lead ore.
Blast furnace/Cupola furnace for Used lead acid battery recycling
Application: second lead melting and reduction
Maximum temperature at hearth: 1800oC
Quality of furnace:
? 16mm steel plate for base of furnace
? 14mm steel for inner support frame
? 12mm steel for out support frame
Material of furnace body:
bottom of furnace: 16mm steel; inner jacket:14mm steel; external jacket: 12 mm steel.
Refractory material: class 1 high-alumina cement, class 1high-alumina brick. Bricks can be used forever.
Working mode: continuously, maximum for 4 month
Tuyere number: 4
Lead Tapping mode: automatically
Slag tapping mode: interval for paste charge and continuously for dust charge
Power consumption:
Motor of blast fan :5.5/7.5 KW ; Motor of Induction fan: 15/22KW
Material that can be charged at this blast furnace/cupola furnace for lead acid battery recycling:
1. Paste from lead acid battery,
2. Dust from lead furnace ,
3. Dross from lead refining kettles,
4. Slag from painting factory
5. Lead concentrate
6. Lead powder
7. and any material containing lead
Burning material: coke (10:1)
Additive : Iron ,swarf, coke, Soda, stone. Contact us for composition of feeding material.
Operators: 4 workers,
Cost of furnace close: very low, 2 worker one day+ half bag cement
Capacity of cupola furnace/ Blast furnace for lead acid battery smelting:
Model SLF-06 with 0.6 square meters hearth melting: 40T-50T/24 hours
Model SLF-07 with 0.7 square meters melting hearth: 50T-60T/24 hours
Model SLF-09 with 0.9 square meters melting hearth :60T-70T/24 hours
Model SLF-10 with 1.0 square meters melting hearth :80T-90T/24 hours
Model SLF- 115 with 1.15 square meters melting hearth : 80T-100T/24 hours
Lead recovery: 95%
Lead recovery rate= recycled lead(kg)/actual existing lead(kg)
Production Rate: 70%
Production rate=lead ingot out(kg)/ input of lead battery (kg)
More photos taken from client’s facility of lead acid battery recycling plant
Contact information:
curbing888@hotmail.com; wechat: curbing1970; Whatsapp:https://wa.me/8613923774083.
For trading of Used lead acid battery scrap, cable scrap, copper powder, please contact linda@san-lan.com