Contact information:
Email:curbing888@hotmail.com; wechat: curbing1970; Whatsapp:+86 139 2377 4083.
Refrigerant extracting machine SD-680
1. Specification of refrigerant extracting machine SD-680
1) Advantage of Refrigerant extracting machine SD-680
1. Two input design, fast recycling, high efficiency
2. Multistage Filters setting, clean the impurity substance
3. Separation function for oil, remove lubrication oil
4. Air separation function, separate the air
5. Automatic stopping after recycling completed
6. Automatic stopping after the collection cylinder is full of refrigerant
7. Overvoltage protection
8. Big capacity of collection cylinder
9. Safe, portable, easy for operating, durable.
2) Datasheet
Model | SD-680 |
Adaptable refrigerant | R404A,R407C,R410A, R134A,R507,R22,R12,R502 |
Cooperated voltage | 220V-240V~50HZ/60HZ |
Compressor power | 3/4HP |
Average recycling rate(normal temperature) | Liquid status:50kg/h Gas status:25kg/h |
Collection cylinder capacity | 15kg/piece |
Overall dimension(mm) | 600*460*1150 (L*W*H) |
Net weight | 75 kg |
2.Connection diagram
1- High pressure input slot;
2- Low pressure input slot
3- Output interface
3.Operating and working flow of machine
1) Recycling refrigerant:
Switch on power
↓
Use punch clamp to punch the hole at the copper tube of AC/refrigerator,connect the punch clamp with the low pressure input slot.
↓
Watch the low pressure gauge, if the indicator is at the positive position, it is ready for recycling work , if the indicator is at negative position , it indicates that the refrigerant has been leaked.
Open the input hand-control valve and output hand-control valve
↓
Open the input hand-control valve of cylinder( red color))
↓
Press “recycle” button ,the indication light indicates the recycling work is starting.
↓
While the low pressure gauge indicates to 0 position, the recycling machine stop working, the indication light extinguishes
↓
Watch the low pressure gauge, it the indicator is still at the 0 position , it indicates that the refrigerant have been fully recycled; If the indicator goes back the positive position, re-start the recycling work from step 1.
↓
Close the input hand-control valve
↓
Remove the connection of punch clamp and copper tube. Work ends.
2) Oil draining out:
All lubrication oil of compressor of refrigerator will be sucked to extracting machine , and then oil and refrigerant will be separated at oil separator. The oil will be store at oil separator, refrigerant will go to compressor and store at refrigerant storage cylinder .
After processing 30 unit refrigerators and 10 units AC, the oil has to be drained out from machine
↓
Switch on the power
↓
Open the oil-draining hand-control valve slowly
↓
Oil drained to the oil bottle
↓
Close the oil-draining hand-control valve.
Oil draining work ends
3) Gas draining out:
At the stationary state, watch the high pressure gauge, if the indicator overcomes 1.5MPa , the gas stored at refrigerant storage cylinder have to be drained out.
↓
Open the gas-draining hand-control valve slowly for 5 seconds
↓
Watch the high pressure gauge, if indicator comes back to position less than 1.2MPa, stop gas-draining. If indicator overcomes to position more than 1.2MPa, re-start gas-draining.
Attention:
To recycle different types of refrigerant, the cylinder has to be empty and become vacuum.
Contact information: